Use of oxygen pulse in predicting Doppler-derived maximal stroke volume in adolescents

Vishwanath Unnithan, Thomas W. Rowland

Research output: Contribution to journalArticle

Abstract

Clinical exercise physiologists and physicians administering stress tests in the young have used oxygen pulse as a surrogate measure of stroke volume. It is important to recognize 1) the accuracy of O2 pulse in predicting maximal stroke volume during exercise, and 2) the normal pattern of O2 pulse during a progressive exercise test. This study examined both of these issues in a cohort of 44 healthy adolescent males and females (ages 14–16 years) who performed routine progressive cycle exercise to exhaustion. Gas exchange variables were measured by standard open circuit techniques. Stroke volume at rest and during exercise was assessed by the Doppler ultrasound method. At peak exercise O2 pulse correlated closely with stroke volume (r = .73) with a SEE of 12.6 ml·beat-1. Values of maximal O2 pulse in nonathletic boys and girls were 13.3 ± 2.5 and 11.0 ± 1.7 ml·beat-1, respectively. After the initial workload, a steady rise was observed in O2 pulse, entirely reflecting an increasing arterial venous oxygen difference, with a slope of approximately 4 ml/beat per 100 watts work load. The findings support the use of O2 pulse as a valid predictor of stroke volume during exercise in youth with a moderately high level of accuracy.
Original languageEnglish
Pages (from-to)412-418
Number of pages7
JournalPediatric Exercise Science
Volume27
Issue number3
DOIs
Publication statusPublished - 2015
Externally publishedYes

Fingerprint

Stroke Volume
Pulse
Exercise
Oxygen
Workload
Exercise Test
Doppler Ultrasonography
Gases
Physicians

Cite this

@article{d121679eb4504df78dbb569a37eb1cde,
title = "Use of oxygen pulse in predicting Doppler-derived maximal stroke volume in adolescents",
abstract = "Clinical exercise physiologists and physicians administering stress tests in the young have used oxygen pulse as a surrogate measure of stroke volume. It is important to recognize 1) the accuracy of O2 pulse in predicting maximal stroke volume during exercise, and 2) the normal pattern of O2 pulse during a progressive exercise test. This study examined both of these issues in a cohort of 44 healthy adolescent males and females (ages 14–16 years) who performed routine progressive cycle exercise to exhaustion. Gas exchange variables were measured by standard open circuit techniques. Stroke volume at rest and during exercise was assessed by the Doppler ultrasound method. At peak exercise O2 pulse correlated closely with stroke volume (r = .73) with a SEE of 12.6 ml·beat-1. Values of maximal O2 pulse in nonathletic boys and girls were 13.3 ± 2.5 and 11.0 ± 1.7 ml·beat-1, respectively. After the initial workload, a steady rise was observed in O2 pulse, entirely reflecting an increasing arterial venous oxygen difference, with a slope of approximately 4 ml/beat per 100 watts work load. The findings support the use of O2 pulse as a valid predictor of stroke volume during exercise in youth with a moderately high level of accuracy.",
author = "Vishwanath Unnithan and Rowland, {Thomas W.}",
year = "2015",
doi = "10.1123/pes.2014-0215",
language = "English",
volume = "27",
pages = "412--418",
journal = "Pediatric Exercise Science",
issn = "0899-8493",
publisher = "Human Kinetics Publishers Inc.",
number = "3",

}

Use of oxygen pulse in predicting Doppler-derived maximal stroke volume in adolescents. / Unnithan, Vishwanath; Rowland, Thomas W.

In: Pediatric Exercise Science, Vol. 27, No. 3, 2015, p. 412-418.

Research output: Contribution to journalArticle

TY - JOUR

T1 - Use of oxygen pulse in predicting Doppler-derived maximal stroke volume in adolescents

AU - Unnithan, Vishwanath

AU - Rowland, Thomas W.

PY - 2015

Y1 - 2015

N2 - Clinical exercise physiologists and physicians administering stress tests in the young have used oxygen pulse as a surrogate measure of stroke volume. It is important to recognize 1) the accuracy of O2 pulse in predicting maximal stroke volume during exercise, and 2) the normal pattern of O2 pulse during a progressive exercise test. This study examined both of these issues in a cohort of 44 healthy adolescent males and females (ages 14–16 years) who performed routine progressive cycle exercise to exhaustion. Gas exchange variables were measured by standard open circuit techniques. Stroke volume at rest and during exercise was assessed by the Doppler ultrasound method. At peak exercise O2 pulse correlated closely with stroke volume (r = .73) with a SEE of 12.6 ml·beat-1. Values of maximal O2 pulse in nonathletic boys and girls were 13.3 ± 2.5 and 11.0 ± 1.7 ml·beat-1, respectively. After the initial workload, a steady rise was observed in O2 pulse, entirely reflecting an increasing arterial venous oxygen difference, with a slope of approximately 4 ml/beat per 100 watts work load. The findings support the use of O2 pulse as a valid predictor of stroke volume during exercise in youth with a moderately high level of accuracy.

AB - Clinical exercise physiologists and physicians administering stress tests in the young have used oxygen pulse as a surrogate measure of stroke volume. It is important to recognize 1) the accuracy of O2 pulse in predicting maximal stroke volume during exercise, and 2) the normal pattern of O2 pulse during a progressive exercise test. This study examined both of these issues in a cohort of 44 healthy adolescent males and females (ages 14–16 years) who performed routine progressive cycle exercise to exhaustion. Gas exchange variables were measured by standard open circuit techniques. Stroke volume at rest and during exercise was assessed by the Doppler ultrasound method. At peak exercise O2 pulse correlated closely with stroke volume (r = .73) with a SEE of 12.6 ml·beat-1. Values of maximal O2 pulse in nonathletic boys and girls were 13.3 ± 2.5 and 11.0 ± 1.7 ml·beat-1, respectively. After the initial workload, a steady rise was observed in O2 pulse, entirely reflecting an increasing arterial venous oxygen difference, with a slope of approximately 4 ml/beat per 100 watts work load. The findings support the use of O2 pulse as a valid predictor of stroke volume during exercise in youth with a moderately high level of accuracy.

U2 - 10.1123/pes.2014-0215

DO - 10.1123/pes.2014-0215

M3 - Article

VL - 27

SP - 412

EP - 418

JO - Pediatric Exercise Science

JF - Pediatric Exercise Science

SN - 0899-8493

IS - 3

ER -