T1 - Tri-axial accelerometry as a simple means to estimate fast running speeds
AU - Wilson, John
AU - Haddow, Olivia
AU - Clark, Jonathan
AU - Irwin, Laura
AU - Easton, Chris
AU - Fudge, Barry
AU - Kayser, Bengt
AU - Pitsiladis, Yannis
PY - 2006
Y1 - 2006
N2 - Little is known about the energy cost of running in the field as most research has been conducted in laboratory settings. Assessment of physical activity using accelerometery is becoming more frequent mainly due to the ease of its use and relatively low cost. Previous studies have failed to observe a linear relationship between accelerometer counts and fast running speeds. For example, activity counts leveled off at approximately 10 000 counts-min1 at a running speed of 9 km-hr1 when measured using uni-axial accelerometry (Brage et al. Med. Sci. Sports Exerc. 35: 1447–1454, 2003).
PURPOSE: To determine the relationship between activity counts measured by tri-axial accelerometry and 1) running speed, 2) heart rate (HR), and 3) oxygen uptake (VO2).
METHODS: Eight trained subjects completed a maximal discontinuous incremental running test on a motorized treadmill (Woodway PPS55 Med, Weil am Rhein, Germany) at speeds corresponding to 8, 10, 12, 14, 16, 18, and 20 km-hr−1, or until volitional exhaustion. Subjects completed 3 min of exercise at each running speed, followed by 3–5 min recovery. Activity counts (tri-axial accelerometer, 3dNXTMBioTel Ltd, Bristol, UK), HR (Suunto t6, Suunto Oy, Vantaa, Finland), and gas exchange variables (breath-by-breath using a quadrupole mass spectrometer, QP9000, Morgan Medical, Gillingham, Kent, UK) were measured throughout exercise.
RESULTS: Activity counts increased linearly with treadmill running speeds (r = 0.985, p < 0.001) (Figure 1). In addition, activity counts during running were significantly correlated with HR (r = 0.988, p < 0.001) and VO2(r = 0.990, P < 0.001).
CONCLUSIONS: The finding of a linear relationship between -TV activity counts measured by tri-axial accelerometry and running speeds up to world-class marathon running pace raises the intriguing possibility that this technology could be used for metabolic monitoring of endurance athletes during free-living, training and competition when combined with other easily obtained measures (e.g. HR and foot-ground contact times).
AB - Little is known about the energy cost of running in the field as most research has been conducted in laboratory settings. Assessment of physical activity using accelerometery is becoming more frequent mainly due to the ease of its use and relatively low cost. Previous studies have failed to observe a linear relationship between accelerometer counts and fast running speeds. For example, activity counts leveled off at approximately 10 000 counts-min1 at a running speed of 9 km-hr1 when measured using uni-axial accelerometry (Brage et al. Med. Sci. Sports Exerc. 35: 1447–1454, 2003).
PURPOSE: To determine the relationship between activity counts measured by tri-axial accelerometry and 1) running speed, 2) heart rate (HR), and 3) oxygen uptake (VO2).
METHODS: Eight trained subjects completed a maximal discontinuous incremental running test on a motorized treadmill (Woodway PPS55 Med, Weil am Rhein, Germany) at speeds corresponding to 8, 10, 12, 14, 16, 18, and 20 km-hr−1, or until volitional exhaustion. Subjects completed 3 min of exercise at each running speed, followed by 3–5 min recovery. Activity counts (tri-axial accelerometer, 3dNXTMBioTel Ltd, Bristol, UK), HR (Suunto t6, Suunto Oy, Vantaa, Finland), and gas exchange variables (breath-by-breath using a quadrupole mass spectrometer, QP9000, Morgan Medical, Gillingham, Kent, UK) were measured throughout exercise.
RESULTS: Activity counts increased linearly with treadmill running speeds (r = 0.985, p < 0.001) (Figure 1). In addition, activity counts during running were significantly correlated with HR (r = 0.988, p < 0.001) and VO2(r = 0.990, P < 0.001).
CONCLUSIONS: The finding of a linear relationship between -TV activity counts measured by tri-axial accelerometry and running speeds up to world-class marathon running pace raises the intriguing possibility that this technology could be used for metabolic monitoring of endurance athletes during free-living, training and competition when combined with other easily obtained measures (e.g. HR and foot-ground contact times).