Skip to main navigation Skip to search Skip to main content

The Use of a High Temperature Wind Tunnel for MT-SOFC Testing—Part II: Use of Computational Fluid Dynamics Software in Order to Study Previous Measurements

  • V. Lawlor
  • , C. Hochenauer
  • , S. Griesser
  • , G. Zauner
  • , G. Buchinger
  • , D. Meissner
  • , A. G. Olabi
  • , K. Klein
  • , S. Kuehn
  • , S. Cordiner
  • , A. Mariani

Research output: Contribution to journalArticlepeer-review

Abstract

Micro-tubular solid oxide fuel cells (MT-SOFCs) are a much smaller version of larger tubular SOFCs. They are operational within seconds and allow a higher power density per volume than the larger version. Hence they are a potential technology for automotive, auxiliary and small scale power supply devices. In this study a commercially available computational fluid dynamic (CFD) software program was used to predict a MT-SOFCs performance when located inside a high temperature wind tunnel experimental apparatus. In Part I, experimentally measured temperature profiles were recorded via thermo-graphic analyses and I/V curves. These measurements were used in this study to establish the predictability and validity of the CFD code and furthermore understand the MT-SOFC attributes measured in Part I. A maximum 4% I/V curve deviation and 6 K temperature deviation between the experimentally measured and model predicted results was observed. Thus, the model predicted the MT-SOFCs performance in the experimental environment very accurately. A very critical observation was the current density and temperature profile across the MT-SOFC that was strongly dependent on the distance from the hydrogen/fuel inlet. Not only was the model validated but also a grid and quantitative solution analysis is explicitly shown and discussed. This resulted in the optimum grid density and the indication that a normally undesirable high grid aspect ratio is acceptable for similar MT-SOFC modeling. These initial simulations and grid/solution analysis are the prerequisite before performing a further study including multiple MT-SOFCs within a stack using different fuels is also envisaged.
Original languageEnglish
Article number61019
JournalJournal of Fuel Cell Science and Technology
Volume8
Issue number6
DOIs
Publication statusPublished - 3 Oct 2011
Externally publishedYes

Fingerprint

Dive into the research topics of 'The Use of a High Temperature Wind Tunnel for MT-SOFC Testing—Part II: Use of Computational Fluid Dynamics Software in Order to Study Previous Measurements'. Together they form a unique fingerprint.

Cite this