Effects of material, coating, design and plaque composition on stent deployment inside a stenotic artery: finite element simulation

A. Schiavone, L.G. Zhao, A.A. Abdel-Wahab

Research output: Contribution to journalArticle

Abstract

Finite-element simulations have been carried out to study the effects of material choice, drug eluting coating and cell design on the mechanical behaviour of stents during deployment inside a stenotic artery. Metallic stents made of materials with lower yield stress and weaker strain hardening tend to experience higher deformation and stronger dogboning and recoiling, but less residual stresses. Drug eluting coatings have limited effect on stent expansion, recoiling, dogboning and residual stresses. Stent expansion is mainly controlled by the radial stiffness of the stent which is closely associated with the stent design. In particular, open-cell design tends to have easier expansion and higher recoiling than closed-cell design. Dogboning is stronger for slotted tube design and open-cell sinusoidal design, but reduced significantly for designs strengthened with longitudinal connective struts. After deployment, the maximum von Mises stress appears to locate at the U-bends of stent cell struts, with varying magnitude that depends on the materials and severity of plastic deformation. For the artery–plaque system, the stresses, especially in the plaque which is in direct contact with the stent, appear to be distinctly different for different stent designs and materials in terms of both distribution and magnitude. The plaque composition also strongly affects the expansion behaviour of the stent–artery system and modifies the stresses on the plaque.
Original languageEnglish
Pages (from-to)479-488
Number of pages10
JournalMaterials science & engineering. C, Biomimetic materials, sensors and systems.
Volume42
DOIs
Publication statusPublished - 1 Sep 2014
Externally publishedYes

Fingerprint

Stents
arteries
coatings
Coatings
Chemical analysis
recoilings
simulation
struts
cells
expansion
Struts
residual stress
drugs
U bends
Residual stresses
strain hardening
plastic deformation
Strain hardening
Pharmaceutical Preparations
stiffness

Keywords

  • stent expansion
  • stenotic artery
  • finite element
  • recoiling
  • dogboning
  • stresses

Cite this

@article{b2bfb21907784073bae3e02ae21810d7,
title = "Effects of material, coating, design and plaque composition on stent deployment inside a stenotic artery: finite element simulation",
abstract = "Finite-element simulations have been carried out to study the effects of material choice, drug eluting coating and cell design on the mechanical behaviour of stents during deployment inside a stenotic artery. Metallic stents made of materials with lower yield stress and weaker strain hardening tend to experience higher deformation and stronger dogboning and recoiling, but less residual stresses. Drug eluting coatings have limited effect on stent expansion, recoiling, dogboning and residual stresses. Stent expansion is mainly controlled by the radial stiffness of the stent which is closely associated with the stent design. In particular, open-cell design tends to have easier expansion and higher recoiling than closed-cell design. Dogboning is stronger for slotted tube design and open-cell sinusoidal design, but reduced significantly for designs strengthened with longitudinal connective struts. After deployment, the maximum von Mises stress appears to locate at the U-bends of stent cell struts, with varying magnitude that depends on the materials and severity of plastic deformation. For the artery–plaque system, the stresses, especially in the plaque which is in direct contact with the stent, appear to be distinctly different for different stent designs and materials in terms of both distribution and magnitude. The plaque composition also strongly affects the expansion behaviour of the stent–artery system and modifies the stresses on the plaque.",
keywords = "stent expansion, stenotic artery, finite element, recoiling, dogboning, stresses",
author = "A. Schiavone and L.G. Zhao and A.A. Abdel-Wahab",
year = "2014",
month = "9",
day = "1",
doi = "10.1016/j.msec.2014.05.057",
language = "English",
volume = "42",
pages = "479--488",
journal = "Materials science & engineering. C, Biomimetic materials, sensors and systems.",
issn = "0928-4931",
publisher = "Elsevier B.V.",

}

TY - JOUR

T1 - Effects of material, coating, design and plaque composition on stent deployment inside a stenotic artery

T2 - finite element simulation

AU - Schiavone, A.

AU - Zhao, L.G.

AU - Abdel-Wahab, A.A.

PY - 2014/9/1

Y1 - 2014/9/1

N2 - Finite-element simulations have been carried out to study the effects of material choice, drug eluting coating and cell design on the mechanical behaviour of stents during deployment inside a stenotic artery. Metallic stents made of materials with lower yield stress and weaker strain hardening tend to experience higher deformation and stronger dogboning and recoiling, but less residual stresses. Drug eluting coatings have limited effect on stent expansion, recoiling, dogboning and residual stresses. Stent expansion is mainly controlled by the radial stiffness of the stent which is closely associated with the stent design. In particular, open-cell design tends to have easier expansion and higher recoiling than closed-cell design. Dogboning is stronger for slotted tube design and open-cell sinusoidal design, but reduced significantly for designs strengthened with longitudinal connective struts. After deployment, the maximum von Mises stress appears to locate at the U-bends of stent cell struts, with varying magnitude that depends on the materials and severity of plastic deformation. For the artery–plaque system, the stresses, especially in the plaque which is in direct contact with the stent, appear to be distinctly different for different stent designs and materials in terms of both distribution and magnitude. The plaque composition also strongly affects the expansion behaviour of the stent–artery system and modifies the stresses on the plaque.

AB - Finite-element simulations have been carried out to study the effects of material choice, drug eluting coating and cell design on the mechanical behaviour of stents during deployment inside a stenotic artery. Metallic stents made of materials with lower yield stress and weaker strain hardening tend to experience higher deformation and stronger dogboning and recoiling, but less residual stresses. Drug eluting coatings have limited effect on stent expansion, recoiling, dogboning and residual stresses. Stent expansion is mainly controlled by the radial stiffness of the stent which is closely associated with the stent design. In particular, open-cell design tends to have easier expansion and higher recoiling than closed-cell design. Dogboning is stronger for slotted tube design and open-cell sinusoidal design, but reduced significantly for designs strengthened with longitudinal connective struts. After deployment, the maximum von Mises stress appears to locate at the U-bends of stent cell struts, with varying magnitude that depends on the materials and severity of plastic deformation. For the artery–plaque system, the stresses, especially in the plaque which is in direct contact with the stent, appear to be distinctly different for different stent designs and materials in terms of both distribution and magnitude. The plaque composition also strongly affects the expansion behaviour of the stent–artery system and modifies the stresses on the plaque.

KW - stent expansion

KW - stenotic artery

KW - finite element

KW - recoiling

KW - dogboning

KW - stresses

U2 - 10.1016/j.msec.2014.05.057

DO - 10.1016/j.msec.2014.05.057

M3 - Article

VL - 42

SP - 479

EP - 488

JO - Materials science & engineering. C, Biomimetic materials, sensors and systems.

JF - Materials science & engineering. C, Biomimetic materials, sensors and systems.

SN - 0928-4931

ER -