TY - JOUR
T1 - Barbell hip-thrust exercise
T2 - test-retest reliability and correlation with isokinetic performance
AU - Dello Iacono, Antonio
AU - Padulo, Johnny
AU - Bešlija, Tea
AU - Halperin, Israel
PY - 2018/8/8
Y1 - 2018/8/8
N2 - The barbell hip-thrust (BHT) exercise is growing in popularity as evident by the large increase in research outputs investigating its utility as a training intervention and a testing tool. The aim of this study was to examine the test-retest reliability of the BHT and its correlation with isokinetic performance. Test-retest reliability was established by correlating the peak force and power outcomes measured with the BHT force-velocity profile test of 20 handball athletes on 2 separate days. The peak force and power measured with the BHT force-velocity profile test of 49 handball athletes were correlated with peak concentric force of the knee flexors and hip extensors measured with an isokinetic device at 2 different velocities (60-180°·s). The correlation between the isokinetic testing scores and the BHT force-velocity profile tests were moderate to large (Pearson r ranges: 0.45-0.86, all p values <0.001). Test-retest reliability of the BHT force-velocity profile was very high as shown with intraclass correlations of 0.94 and 0.99 for peak force and 0.97 and 0.99 for peak power measures. The BHT force-velocity profile can serve as a tentative substitute in cases that athletes do not have access to an isokinetic device, given the moderate to large correlations between them. Moreover, the BHT force-velocity profile was shown to be very reliable, thus providing coaches and scientists a range of day-to-day performance variability in this exercise.
AB - The barbell hip-thrust (BHT) exercise is growing in popularity as evident by the large increase in research outputs investigating its utility as a training intervention and a testing tool. The aim of this study was to examine the test-retest reliability of the BHT and its correlation with isokinetic performance. Test-retest reliability was established by correlating the peak force and power outcomes measured with the BHT force-velocity profile test of 20 handball athletes on 2 separate days. The peak force and power measured with the BHT force-velocity profile test of 49 handball athletes were correlated with peak concentric force of the knee flexors and hip extensors measured with an isokinetic device at 2 different velocities (60-180°·s). The correlation between the isokinetic testing scores and the BHT force-velocity profile tests were moderate to large (Pearson r ranges: 0.45-0.86, all p values <0.001). Test-retest reliability of the BHT force-velocity profile was very high as shown with intraclass correlations of 0.94 and 0.99 for peak force and 0.97 and 0.99 for peak power measures. The BHT force-velocity profile can serve as a tentative substitute in cases that athletes do not have access to an isokinetic device, given the moderate to large correlations between them. Moreover, the BHT force-velocity profile was shown to be very reliable, thus providing coaches and scientists a range of day-to-day performance variability in this exercise.
U2 - 10.1519/JSC.0000000000002779
DO - 10.1519/JSC.0000000000002779
M3 - Article
C2 - 30095734
SN - 1064-8011
JO - Journal of Strength and Conditioning Research
JF - Journal of Strength and Conditioning Research
M1 - 2779
ER -